252569
regulation screw for minimum thermal load as far as it will go,
in order to attain minimum thermal load.
• When adapting the appliance to natural gas, release the
minimum thermal load regulation screw in order to attain
minimum thermal load, but do not rotate it by more than 1.5 turns.
Cooker burner
1 Burner crown cover
2 Burner crown with cover support
3 Thermo-element
4 Spark plug
5 Nozzle
Triple burner
5 Nozzle
To leave the adjustment elements accessible, please observe the
following instructions:
• Remove the support grid and burner covers with respective
crowns.
• In double burners, adjustment elements are accessible behind
the main nozzle protective plate.
• Remove the control knobs, including the gaskets.
Gas valve
Minimum thermal load regulation valve
Adjustment elements